Learn to connect what a machine does with what its signals say. These three browser-based stations let you teach a virtual robot, connect a simulated sensor circuit and investigate a stopped conveyor.
Open the mechatronics stationsStart with observation, not a guessed repair
Keep four things separate: the physical target or part, the sensor indication, the controller’s command and the machine’s actual movement. A TRUE command is evidence of a request, not proof that a mechanism moved. The stations display these states so you can compare them while the model runs.
Three hands-on stations
1. Teach a pick-and-place robot
Jog a generic two-axis carriage to the pickup and placement locations, then teach those positions. Run the sequence and watch part presence, grip confirmation and return-home behavior. The station checks two transfers and a return home with the gripper released. If the cycle stops, inspect the position or feedback that the next step needs rather than changing every setting.
2. Connect a simulated PNP sensor
With the simulation’s power OFF, connect a normally-open three-wire 24 V DC PNP sensor to a compatible sinking PLC input. The model uses brown for positive supply, blue for 0 V and black for the switched output; the input common also needs the correct reference. Then turn simulated power ON and test target clear → detected → clear. This complete change is more informative than seeing one indicator stay on.
3. Diagnose a stopped conveyor
Start the model and feed a part. Compare the part’s position, sensor state, motor command and movement. Locate the exit-detection problem, stop the simulation before adjusting the sensor, then prove recovery by transferring three parts and checking Stop/Restart behavior.
Try this before opening a hint
A part is visibly at the conveyor exit, but the exit input remains FALSE. What should you inspect first?
Reveal the diagnostic reasoning
Check whether the simulated sensor’s detection area actually reaches the part, then compare its indication with the controller input. A visible part does not guarantee that the sensor detects it. In this station, correcting the exit-sensor aim is the intended repair. On real equipment, alignment is only one possibility; wiring, configuration and hardware faults require their own safe diagnostic process.
A repeatable practice method
- Read the objective and identify what would count as success.
- Run the model and describe the first unexpected event.
- Compare the relevant signals before making one change.
- Use a hint if you are stuck, then explain why that hint matters.
- Select Check my station and repeat the test after the repair.
Practice the stations → · Prefer a short coding task?
Model limits and references
These are generic educational simulations, not commissioning instructions, vendor emulators or certification. No real hardware is connected. Robot coordinates and timing are invented teaching values. The wiring station covers one PNP example, not NPN, mains, protective circuits or actual device pinouts. Ordinary process feedback and a normal Stop command are not safety functions. Do not copy these motions or connections onto equipment.
For manufacturer background, see Balluff’s three-wire sensor explanation and Universal Robots’ description of feedback waits. Always use the exact equipment manual and your site’s authorized procedures for real machinery.